TOP
0
0
即日起~6/30,暑期閱讀書展,好書7折起
Approved Document B: Fire Safety - Volume 2: Buildings other than dwellings
滿額折

Approved Document B: Fire Safety - Volume 2: Buildings other than dwellings

商品資訊

定價
:NT$ 1375 元
優惠價
951306
領券後再享88折起
無庫存,下單後進貨(到貨天數約45-60天)
可得紅利積點:39 點
相關商品
商品簡介

商品簡介

Approved Document B of the Building Regulations covers fire safety matters within and around buildings. Published in two volumes, Volume 1 deals solely with dwellings, including blocks of flats, while this volume - Volume 2 - deals with all other types of building cover by the Building Regulations and comes into effect on 30 August 2019. The aim of each volume is to set out the guidelines that need to be followed in order to prevent the spread of fire over linings, such as walls and ceilings.

Each volume also states what materials can be used and what British Standards each should conform to, to ensure that they provide the required level of protection. This new edition of Approved Document B incorporates the following amendments:*November 2018 which took effect on 21 December 2018*December 2018 which took effect on 21 January 2019Full details on the above amendment booklets can be found at - https://assets.publishing.service.gov.uk/government/uploads/system/uploads/attachment_data/file/795931/AD_B_Apr2019_amend.pdf Main changes in the 2019 edition are:*This volume of this approved document supports requirements B1 to B5 of Schedule 1 to the*Building Regulations 2010 as well as regulations 6(3), 7(2) and 38. *Approved Document B has been redrafted to clarify its language and content in line with the Department's style guide for approved documents.

*This edition of the approved document replaces the 2006 edition including all amendments. There are no changes from the previous edition to the technical guidance within Approved Document B. *As well as furthering the use of plain English, the document has been significantly restructured:- the design of blocks of flats has moved from volume 2 to volume 1- guidance on the design of sprinkler systems has been consolidated to a new Appendix- European fire classifications are provided within the main body of the document with transposition to a national classification provided in Appendix B- the guidance on external stairs has been consolidated- fire safety information (under regulation 38) has been moved from an appendix into a new section- the guidance on insulating core panels has moved from an appendix into the Wall and Ceiling Linings section- the guidance on fire dampers and ventilation systems has been consolidated.

您曾經瀏覽過的商品

購物須知

外文書商品之書封,為出版社提供之樣本。實際出貨商品,以出版社所提供之現有版本為主。部份書籍,因出版社供應狀況特殊,匯率將依實際狀況做調整。

無庫存之商品,在您完成訂單程序之後,將以空運的方式為你下單調貨。為了縮短等待的時間,建議您將外文書與其他商品分開下單,以獲得最快的取貨速度,平均調貨時間為1~2個月。

為了保護您的權益,「三民網路書店」提供會員七日商品鑑賞期(收到商品為起始日)。

若要辦理退貨,請在商品鑑賞期內寄回,且商品必須是全新狀態與完整包裝(商品、附件、發票、隨貨贈品等)否則恕不接受退貨。

優惠價:95 1306
無庫存,下單後進貨
(到貨天數約45-60天)

暢銷榜

客服中心

收藏

會員專區